Documented from the first sprint
Requirements, architecture, risk controls and test evidence are written and linked as the software is built, following an IEC 62304-aligned life cycle and your quality procedures.
Software for medical devices and SaMD, built with an IEC 62304-aligned process, risk documentation and traceability your regulatory team can submit.

Standards and regulations we design toWe build to these. They are not certifications, and we do not claim any.
FHIR APIs
HL7 v2 interfaces
Designed to support HIPAATrusted by healthcare and technology teams
Medical device software development builds software that is a medical device (SaMD) or runs on or connects to one, under a documented life cycle: requirements, risk management, verification and traceability. Teams usually follow IEC 62304 for the software life cycle and ISO 14971 for risk, inside the manufacturer's quality system, so the FDA submission has the evidence it needs.
| Software as a Medical Device (SaMD) | Software in or connected to a device | |
|---|---|---|
| What it is | Software that performs a medical purpose on its own, such as analysing images or readings | Firmware, companion apps and cloud services that work with a physical device |
| Regulation | Regulated as a device; FDA pathway depends on risk class and intended use | The device is regulated; the software is part of its design history |
| What we deliver | Life-cycle documentation, traceability, verification evidence and the software itself | Apps, cloud and integration code with the same documentation discipline |
| Who owns the submission | Your regulatory team or consultant | Your regulatory team or consultant |
Sources: FDA Digital Health Center of Excellence · Our guide: SaMD vs embedded medical device software · Our guide: medical device software development cost
Last reviewed: by the Groovy Web healthcare team
From requirements to verified releases. We build the software and the evidence behind it, inside your quality system, so audits and submissions are not a scramble at the end.




Requirements, architecture, risk controls and test evidence are written and linked as the software is built, following an IEC 62304-aligned life cycle and your quality procedures.
Software that performs a medical purpose on its own, such as analysing readings or images, with the intended use and risk class agreed with your regulatory team before design starts.
Patient and clinician apps that pair with a device over Bluetooth or the cloud, with secure data handling and clear limits on what the app may claim.
Cloud services that receive device data, store it in US regions and share it with EHRs through FHIR or HL7 where the product needs it.
Unit, integration and system tests mapped to requirements and risk controls, with reports your quality team can file.
Connections to EHRs and clinical systems so device data reaches the chart, built and tested against vendor sandboxes.
Threat modelling, secure updates, access control and logging, documented for the cybersecurity sections of a submission.

Teams with a regulatory plan who need engineering capacity.
First SaMD or companion app release.
Apps and cloud for existing devices.
Features that cross into device territory.
Software for studies and pilots.
Your regulatory plan sets the pace; we build to it.
Agree intended use, risk class and the documents your pathway needs.
Software requirements, architecture and risk controls, traceable from the start.
Working software with tests mapped to requirements and risks.
Device, cloud and EHR connections tested end to end.
Controlled releases, change records and post-market fixes.
The frameworks we build to. We follow them inside your quality system; we do not hold these certifications ourselves.
Medical device software life cycle processes.
Risk management for medical devices.
Quality management system, held by the manufacturer.
For sharing device data with EHRs.
Device data is often PHI. These controls are built in from the first sprint.
How we protect patient dataTLS on every connection and encrypted storage.
Who accessed which record, when and from where.
Each user sees only what their role needs.
Signed releases and controlled update paths.
Patient data stays in US cloud regions, in your account.
We sign a Business Associate Agreement before any access to PHI.
Tell us the device, intended use and where you are in your regulatory plan. After a call, our team sends a written scope with pricing.
Get a free scoped estimate
Tell us about your project and we'll get back to you within 24 hours with a game plan.
Mon-Fri, 8AM-12PM EST
4hr overlap with US Eastern